Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Description

Qty

Manufacturer

Part Number

Voltage
[V]

Current
[A]

Power
[VA]

PDU Plugs

Ethernet
Req'd?

Rack U’s Req’d
(1U = 1.75”)

Controlling Software
[Etalon/KPF]

WMKO Heat Exchanger

1

WMKO

-

1

-

6

N/A

Etalon Rack Network Switch

1

Aruba

2530-24G

1

-

1

N/A

Etalon Rack PDU

1

Eaton

EMAT08-10

-

1

1

KPF

Etalon digital acquisition interface

2

MCDAQ

USB-1808X

USB

0

-

1

Etalon

Laser current controller

1

Custom

-

110

60

1

-

3

-

Temperature controller

2

Vescent

SLICE-QT

110

50

1

-

3 (for both)

Etalon

Ion getter pump

1

Modion (TBD)

C-1765M

110

5

1

-

-

Etalon

Vacuum gauge

1

Thyracont

VSM79

110

5

1

-

-

Etalon

Etalon computer

1

InoNet (TBD)

MAYFLOWER-ID/i7-8700Rp

110

250

2

11

2

Etalon

Notes:

  • For “Controlling Software” column:

    • “Etalon” = device is only controlled by software on etalon PC;

    • “KPF” = device needs to be controlled by KPF instrument control software

  • For “Etalon computer”:

    • any 19” server with Linux OS (preferred: Ubuntu) with at least 4 cores. >=1TB SSD, >=2TB HDD, >=16GB RAM will work

    • redundant power supply recommended (included in table)

    • necessary interfaces (TBD): 4x USB 2.0, 2x USB 3.0

...

Other Facility Services

Service

Description

Ethernet

Ethernet line from the KPF main switch to the etalon rack switch.

Compressed Air

To float the optical table shared with the calibration unit.

Glycol

For the WMKO heat exchanger in the top of the etalon rack.

Dry Air

?

Other?

?

...