Sub-system
...
PDUs (needed and/or already installed)
Sub-system | Function | Physical Location | Key Word Control | Status | 05:04 | 00:15 | Sunset/Dome open | 05:19 | 02:00 | PCS: fine screen, phasing | 07:20 | 00:10 | Switch to OSIRIS | 07:30 | 00:30 | Basic AO/OSIRIS checkout Stability IQ on bright star | 08:00 | 01:00 | OSIRIS HAM Check HD 90700 (single) HD 90823 (double) | 09:00 | 01:00 | OSIRIS post-service Server functionality post OS upgrade Orientation Offsets between OSPEC/OSIMG Offsets between OSPEC scales | 10:00 | 01:00 | OSIRIS Tellurics w/ & w/o TRICK dichroic Mostly SPEC Simultaneous IMAG if can | 11:00 | 01:00 | OSIRIS blank sky for wavelength solution | 12:00 | 01:00 | Repeat Tellurics or Imager throughputs as function of pupil | 13:00 | 00:10 | Switch to SSC | 13:10 | 00:50 | 45-star pointing test CW | 14:00 | 00:50 | 45-star pointing test CCW | 14:52 | - | 12-degree twilight | 15:33 | - | SunriseStatus | Keyword Control |
CCD crate power supply | CCD control crate | Footlocker inside HIRES enclosure. Outlet #1 | PDU Needed | N/A | |||||||||||||||||||||||||||||||||||||||||||
Fan Control | Cooling for CCD controller | Footlocker in HIRES enclosure. Outlet #2 | PDU Needed | N/A | |||||||||||||||||||||||||||||||||||||||||||
Motor Control crate power supply | Motor control Crate | Old K1 laser enclosure on K1 Platform | PDU Needed | N/A | |||||||||||||||||||||||||||||||||||||||||||
Galil controllers | Mechanism control | Old K1 laser enclosure on K1 Platform | PDU Needed | N/A | |||||||||||||||||||||||||||||||||||||||||||
Amplifiers | Part of the mechanism control? | Old K1 laser enclosure on K1 Platform | PDU Needed | N/A | |||||||||||||||||||||||||||||||||||||||||||
Interconnect | Another aspect of the mechanism control? | Old K1 laser enclosure on K1 Platform | PDU Needed | N/A | |||||||||||||||||||||||||||||||||||||||||||
Exposure Meter | Separate system used for controlling exposure time to achieve a desired S/N | Old K1 laser enclosure on K1 Platform | PDU Needed | N/A | |||||||||||||||||||||||||||||||||||||||||||
Terminal Server | For access to the control crates | Old K1 laser enclosure on K1 Platform | PDU Needed | N/A | |||||||||||||||||||||||||||||||||||||||||||
Ethernet Converter | Fiber to/from ethernet conversion | Old K1 laser enclosure on K1 Platform | PDU Needed | N/A | |||||||||||||||||||||||||||||||||||||||||||
Serial Converter | Fiber to/from serial conversion(?) | Old K1 laser enclosure on K1 Platform | PDU Needed | N/A | |||||||||||||||||||||||||||||||||||||||||||
“Cylinder control” | Unknown what this is or does. Has a sticker on it saying “HIRES” | Old K1 laser enclosure on K1 Platform. This has its own separate outlet | PDU Needed | N/A |