A Uniblitz VED24 shutter controllers is located within the electronics drawer of the Vac Cart. This location was chosen due to a length restriction on the shutter cable between the VED24 and the shutter within the scrambler (Uniblitz said the maximum cable length was 30 ft). As such, the Vac Cart was close enough but the Aux Rack was a bit too far away.

The Scrambler Timed shutter is larger than the other shutters within the system, and as such requires different settings on its VED24 controller, as described below.

...

Relevant Devices

Description

Qty

Source

Part Number

Notes

Shutter Controller

4

1

Uniblitz

VED24

Shutter

4

1

Uniblitz

DSS25B

NS65B1T0-VED

65mm Optical Shutter

Bi-stable (only requires power for transitions)

Ordering Options:

Image Added

Note: as of 2021 the electronic sync option was not available for this shutter. Uniblitz said that option was only possible for this shutter as part of a custom, large-quantity order.

...

Relevant Functional Block Diagram

...

Cable Details

Cable

Qty

Details

Cal. Unit. Sci/Sky Arm Shutter (BNC)

1

See Aux Rack External Cables

Cal Unit Simultaneous Cal Shutter (BNC)

1

See Aux Rack External Cables

SoCal Sci Fiber Shutter (BNC)

1

See Aux Rack External Cables

SoCal Cal Fiber Scrambler Shutter (BNC)

1

See Aux Rack External Cables

Uniblitz Custom-Supplied Length 510F Cable

4

Ships with Uniblitz VED24 Shutter Controller

Uniblitz-Supplied 5M203D Cable

4

Ships with Uniblitz VED24 Shutter Controller(30-feet Long)

1

View file
nameQuote # 071018SS4.pdf

...

Photos of Devices

...

Installation Instructions

The settings below must only be used for the NS65B shutter, or damage will result.

The shutter controller has a set of DIN “Function Switches” (second from right in image below) and an Octal switch for “Pulse Duration” (far right in image below) that need to be configured for the particular shutter being used:

...

The function switch has the following settings:

...

For the DSS25B NS65B shutters the function switch and pulse duration settings are:

...

Note the setting for Switch 1 does not depend on the shutter type, but should be set to ‘UP’ for ‘LOCAL’ (this disables the USB port and enables the BNC Pulse Input):

Note also that there is also a toggle switch on the front that sets the ‘Normally Open’ or ‘Normally Closed’ polarity of the switch (second from left in image above). The manual is not clear on how this affects a bi-stable shutter. For consistency within KPF, all shutter controllers should be set to ‘N.O.’. Each KPF VED has a label on the front to indicate this, as show in the picture above.

...

Description

File

Source

1

Uniblitz VED24 Controller Datasheet

View file
nameVED24 Datasheet.pdf

https://www.uniblitz.com/products/ved24-shutter-driver/

2

Uniblitz VED24 Controller Manual

View file
nameVED24-User-Manual-1.42_Rev_C.pdf

3

Uniblitz DSS25B NS65B Shutter Datasheet

View file
nameuniblitz-dss25bns65b-datasheet.pdf

https://www.uniblitz.com/products/dss25bns65b/

4

Uniblitz DSS25B NS65B Shutter Solid Model

View file
namedss25bns65b-3d-outline-model.zip