Table of Contents:


Relevant Devices

Description

Qty

Source

Part Number

Barometer/Humidity Sensor

1

Vaisala

PTU300

Serial Interface Cable

1

Vaisala

19446ZZ

RS-232 to Ethernet Adapter

1

Lantronix

UDS2100

This is the version with two serial ports (but standard 9-pin RS-232 connectors)


Relevant Functional Block Diagram


Software Actions

Action

Notes

1

Read pressure value

Value reported as telemetry (see below)

2

Read temperature value

Value reported as telemetry (see below)

3

Read relative humidity value

Value reported as telemetry (see below)


Required Adjustable Settings

Setting

When Needed

Notes

Build

Observing

Maintenance

Pressure measurement frequency

Yes

No

Maybe

Set in configuration file. If this needs to be changed, edit configuration file, re-install, and then restart dispatcher.

Temperature measurement frequency

Yes

No

Maybe

See pressure.

Relative humidity measurement frequency

Yes

No

Maybe

See pressure.


Required Telemetry

Parameter

Report Frequency

Purpose

Notes

1

Pressure measurement

Once every 5 sec [TBC]

Environmental monitoring

Managed through configuration file

2

Temperature measurement

Once every 5 sec [TBC]

Environmental monitoring

See pressure.

3

Relative humidity measurement

Once every 5 sec [TBC]

Environmental monitoring

See pressure.


Required Alarms

Parameter

Threshold

Notes

1

Time of last connection

More than 10 seconds

2


Relevant Datasheets & Manuals


Relevant Software

Description

Files

1

Python 2 software written by a student some years back. These lines of code were used to read values from the Vaisala while it was installed at Keck.

That installation was using a USB interface on a Windows machine. Not sure if the current serial interface will change anything here.

2

As part of the KROOT distribution, there is a SerialStream interface which manages connections to and from serial hosts. This includes managing Lantronix connections.


Dispatcher Implementation

Keyword

Value

Type

CONN

On or Off - controls whether or not the connection to the Lantronix is on or off.

Can be used if the Vaisala needs to be unplugged and moved, for example.

Boolean which is writable.

IP

IP address of the Lantronix box.

String set in the configuration file, only readable.

PORT

Port for the Lantronix box that talks to the correct serial device.

String set in configuration file, only readable.

RETVAL

Value returned by Vaisala.

String. The format is set in the configuration file. Only readable.

TIME

Time stamp of when the last RETVAL was received.

Unix timestamp (binary) or time stamp (ascii). Only readable.

PRES

Pressure value in units of hPa.

Double value from RETVAL, read only.

RELH

Relative humidity in %.

Double value from RETVAL, read only.

TEMP

Temperature in deg C.

Double value from RETVAL, read only.

DISPSTA

Dispatcher status.

Enum and read only. If value is 4 or “Not Connected” the connection to the Vaisala or the Lantonix is not available. If value is 3 or “Connecting” the dispatcher is attempting to connect to the Vaisala through the Lantronix.

Configuration

Value

Explanation

ip

192.168.23.102

IP address of the Lantronix box.

port

10001

Port that is used for Vaisala, this is port 1.

format_str

form 9.4 "P=" P " " U6 6.4 "T=" T " " U3 6.4 "RH=" RH " " U4 \r \n

Format statement of the output from the Vaisala. At dispatcher start up and at every new connection, this value is sent to the Vaisala. The #.# sets the number of characters (first # ) and the second # sets the number of characters after the decimal point. There must be a space between the characters that notes what the value is (such as P=) and the actual value (the P). The code uses the characters (P=, RH= or T=) to determine what the next value is.

poll_time

5

Time between reads of the Vaisala in seconds.