NIRC2 Readiness

NIRC2 Readiness

Sub-system PDUs (needed and/or already installed)

Sub-system

Function

Physical Location

Status

Keyword Control

NIRC2 motion control and and detector host computer (waikoko)

Motion control, cold head speed control, temperature control and monitoring, detector operation with old electronics (transputers)

K2 Computer Room

PDU installed

YES

NIRC2 detector host computer (waikoko-new)

Detector operation with new Archon controller.

K2 Computer Room

PDU installed

YES

BlackBox SCS to FO converter

Detector operation with old transputer electronics

K2 Computer Room

PDU installed

YES

AT-MC15

Ethernet to 10BASE converter for AO vault and CCR terminal servers

K2 Computer Room

PDU installed

YES

Emulex Terminal Server

Communications with CCD speed controller

K2 Computer Room

PDU installed

YES

DGH A1000

RS-232 to RS-485 serial communication converter for CCR speed controller

K2 Computer Room

PDU installed

YES

CCR speed controller

Controls the speed of the two CCR cold heads

K2 Machinery Room. One PDU outlet outlet required. PDU KE 192.168.80.102 A1.

PDU installed

YES

Keyword history machine (moolelo)

NIRC2 keyword history dispatcher

K1 Computer Room. TCSU rack.

PDU installed

YES

Emulex Terminal Server

Communications with motors and Lakeshores for temperature monitoring and control

K2 AO Electronics Vault. PDU KG 192.168.3.12 A3.

PDU installed

YES

DGH A1000

RS-232 to RS-485 serial communication converter for motors

K2 AO Electronics Vault. PDU KF 192.168.3.11 A3.

PDU Installed

YES

DGH A1000

RS-232 to RS-485 serial communication converter for pupil rotator

K2 AO Electronics Vault. PDU KF 192.168.3.11 A3.

PDU Installed

YES

Lakeshore 340

Cryogenic temperature control

K2 AO Electronics Vault. PDU KG 192.168.3.12 A1.

PDU Installed

YES

Lakeshore 218

Cryogenic temperature monitoring

K2 AO Electronics Vault. PDU KG 192.168.3.12 A2.

PDU Installed

YES

Motor power supply

Power supply for motors

K2 AO Electronics Vault. PDU KG 192.168.3.12 A7.

PDU Installed

YES

Heater power supply

Power supply for heater used in cryogenic temperature control

K2 AO Electronics Vault. PDU KG 192.168.3.12 A8.

PDU Installed

YES

DGH A1000

RS-232 to RS-485 serial communication converter for spectral lamp control

K2 AO Electronics Vault. PDU KF 192.168.3.11 A3.

PDU Installed

YES

Power supply for calibration lamps

Arc lamps and white light source

K2 AO Electronics Vault. PDU KG 192.168.3.12 A6.

PDU Installed

YES

Network switch for Archon controller

Communications between waikoko-new and the Archon controller

K2 AO Electronics Vault. Network switch IP address 192.168.3.3. PDU KF 192.168.3.11 A8.

PDU Installed

YES

Vacuum pump controller

Controls backup roughing and turbo vacuum pumps

K2 AO enclosure. NIRC2 PDU in AO 192.168.3.10 outlet A8.

PDU Installed

YES

Solenoid valve

Controls vacuum port from the backup turbo pump to the dewar

K2 AO enclosure. Power output from the vacuum pump controller.

No PDU needed

N/A

Turbo vacuum pump

Used for servicing dewar and to ensure vacuum inside dewar if there is an unintended warm up

K2 AO enclosure. Power output from the vacuum pump controller.

No PDU needed

N/A

Oil-less roughing vacuum pump

Used for servicing dewar and to ensure vacuum inside dewar if there is an unintended warm up

K2 AO enclosure. Power output from the vacuum pump controller.

No PDU needed

N/A

Transputers

Old detector electronics

K2 AO enclosure. Electronics cabinet to be dismantled once we start science operations with Archon controller.

No PDU needed

N/A

Archon controller

New detector electronics

K2 AO enclosure. NIRC2 PDU in AO 192.168.3.10 outlet A1.

PDU Installed

YES

USB/FO converter power supply

USB/FO converter for signal analyzer attached to Archon controller

K2 AO enclosure. NIRC2 PDU in AO 192.168.3.10 outlet A3.

PDU Installed

YES

Additional information

  • Need 2 PDUs to cover all NIRC2 devices in the K2 AO Electronics Vault (DONE).

 









Related content

HIRES Readiness
HIRES Readiness
More like this
NIRSPEC Readiness
NIRSPEC Readiness
More like this
DEIMOS Readiness
DEIMOS Readiness
More like this
NIRC2
More like this
Remote control of instruments components for UNO
Remote control of instruments components for UNO
More like this
Alarms
More like this