Sub-system PDUs (needed and/or already installed)

Sub-system

Function

Physical Location

Status

Keyword Control

DEIMOS private network switch

Manage private network

K2 Computer Room. DEIMOS rack.

PDU installed

YES

DEIMOS primary host (polo)

Science and FCS CCD high-level software, ion pump dispatchers, PDU software for ion pump controllers

K2 Computer Room. DEIMOS rack.

PDU installed

YES

DEIMOS secondary host (keamano)

Motion control daemons

K2 Computer Room. DEIMOS rack.

PDU installed

YES

DEIMOS rotator control host (roto)

Rotator software

K2 Computer Room. DEIMOS rack.

PDU installed

YES

FCS CCD VME crate

FCS detector low-level software

K2 Computer Room. DEIMOS rack.

PDU installed

YES

Science CCD VME crate

Science detector low-level software

K2 Computer Room. DEIMOS rack.

PDU installed

YES

DEIMOS Virtual Machine (vm-deimos)

Autofill, FCS configuration, monitoring, sounds, and auxiliary daemons

K1 Computer Room. UNO readiness of VM rack is to be requested by Computer Support.

No PDU available

NO

Keyword history machine (moolelo)

DEIMOS keyword history dispatcher

K1 Computer Room. TCSU rack.

PDU installed?

YES?

Sybase server (waiaha)

DEIMOS configurable elements database

K1 Computer Room. This is a VM. UNO readiness of VM rack is to be requested by Computer Support.

No PDU available

NO

Guider host computer (waimanu)

Guider control software

K2 Computer Room. DEIMOS rack.

PDU installed

YES

Barrel Lantronix terminal server

Serial communications with ion pump controllers, slitmask barcode reader, tent mirror piezo controller, Galil 1500 controllers for optomechanical stages.

DEIMOS electronics ring Bay 3

PDU Needed

NO

Guider camera controller

Controller for guider camera

DEIMOS electronics ring Bay 2. Remote power control available.

No PDU needed

YES

SCSI to fiber converteer

Guider camera communications and data transfer

DEIMOS electronics ring Bay 2. Remote power control available.

No PDU needed

YES

HP 34970A data logger

Read temperature sensors located on the instrument structure

DEIMOS electronics ring Bay 2. Not used.

No PDU needed

N/A

PI P-845 piezo controller

Controller for tent mirror piezo actuator

DEIMOS electronics ring Bay 2

PDU Needed

NO

Galil 1500 motion controller #1

Calibration lamps, science filter wheel, dewar translation stage, guider filter wheel, guider focus stage

DEIMOS electronics ring Bay 1

PDU Needed

NO

Galil 1500 motion controller #2

Hatch, slitmask selector, slitmask arm, grating selector, grating tilts

DEIMOS electronics ring Bay 11

PDU Needed

NO

LN2 can ion pump controller

Controller for LN2 canister ion pump

DEIMOS electronics ring Bay 11

PDU installed

YES

Detector dewar ion pump controller

Controller for detector dewar ion pump

DEIMOS electronics ring Bay 11

PDU installed

YES

D-Link DGS-105 network switch

Communications with ion pump controllers and PDU

DEIMOS electronics ring Bay 11

PDU installed

YES

10Base2 to RJ45 converter

Converter to connect DEIMOS private Thinnet BNC cable with D-Link switch

FCS CCD controller

Controller for FCS CCD

DEIMOS electronics ring Bay 10

PDU Needed

NO

Science CCD controller

Controller for Science CCD mosaic

DEIMOS electronics ring Bay 9

No PDU needed

N/A

Science CCD controller power supply

Power supply for the science CCD controller

DEIMOS electronics ring Bay 8

PDU Needed

NO

Shutter controller

Controller for detector shutter

DEIMOS electronics ring Bay 8

PDU Needed

NO

Autofill controller

DEIMOS autofill system

DEIMOS cradle Bay A

PDU Needed

NO

Galil DMC-4240 motion controller

Rotator controller

DEIMOS cradle Bay C

PDU Needed

NO

Cradle Lantronix terminal server

Serial communication with CCD controller UPS and handheld barcode reader

DEIMOS cradle Bay D

PDU Needed

NO

Netgear EN104 hub

10Base-T Ethernet hub for rotator Galil controller and barrel Lantronix terminal server

DEIMOS cradle Bay D

PDU Needed

NO

Additional information

  • All components in the DEIMOS cradle (4) can be connected to an 8-port PDU to be installed in the Bay D. A power cable for the autofill controller would need to be routed from Bay A to be D. There is already a power cable from the rotator controller in Bay C to Bay D.

 