Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Added some notes on the test and also the test data files.

...

Table of Contents:

Table of Contents
minLevel1
maxLevel7
excludeTable of Contents:

...

Test Description:

Leak test after chamber has been pumping down for 5.5 days, after first installation of bench support cart and MLI inside chamber.

...

Test Data:

Note data in these files go back to midnight, or 10 hrs before test was started.

Description

File

kpfvac service telemetry

(vac gauges, vac pump telemetry)

View file
nameLeak test Sept 23, 2021 kpfvac data.csv

kpfmet service telemetry

(Vaisala temp, pressure, RH)

View file
nameLeak test Sept 23, 2021 kpfmet data.csv

...

Test Log:

Time

Who

Description

10:07 am

SG

Gate valve closed

10:09 am

SG

Turbo pump stopped

12:50 pm

SG

Chamber pressure over last hour looks fairly linear (by eye), with a rate of +0.0027 Torr per hour.

1:40 pm

SG

Gate valve power outlet on PDU turned back on. Gate valve remained closed as expected.

3:02 pm

SG

Will updated the dispatcher for VCH_LOVAC and VCH_HIVAC

3:30 pm

SG

Pressures on either side of gate basically equal. Turned turbo pump on to force lower pressure on pump side of gate valve.

3:32 pm

SG

Opened gate valve