Sub-system PDUs (needed and/or already installed)
Sub-system | Function | Physical Location | Status | Keyword Control |
NIRC2 motion control and and detector host computer (waikoko) | Motion control, cold head speed control, temperature control and monitoring, detector operation with old electronics (transputers) | K2 Computer Room | PDU installed |
YES |
NIRC2 detector host computer (waikoko-new) | Detector operation with new Archon controller. | K2 Computer Room | PDU installed | YES |
BlackBox SCS to FO converter | Detector operation with old transputer electronics | K2 Computer Room | PDU installed |
YES |
AT-MC15 | Ethernet to 10BASE converter for AO vault and CCR terminal servers | K2 Computer Room | PDU installed |
YES |
Emulex Terminal Server | Communications with CCD speed controller | K2 Computer Room | PDU installed |
YES |
DGH A1000 | RS-232 to RS-485 serial communication converter for CCR speed controller | K2 Computer Room | PDU installed |
YES |
CCR speed controller | Controls the speed of the two CCR cold heads | K2 |
Machinery Room. One PDU outlet outlet required. PDU KE 192.168.80.102 A1. | PDU installed |
YES |
Keyword history machine (moolelo) | NIRC2 keyword history dispatcher |
K1 Computer Room |
. TCSU rack. | PDU installed |
YES |
Emulex Terminal Server | Communications with motors and Lakeshores for temperature monitoring and control | K2 AO Electronics Vault. PDU KG 192.168.3.12 A3. | PDU |
installed |
YES | |||
DGH A1000 | RS-232 to RS-485 serial communication converter for motors | K2 AO Electronics Vault. PDU KF 192.168.3.11 A3. | PDU |
Installed |
YES | |||
DGH A1000 | RS-232 to RS-485 serial communication converter for pupil rotator | K2 AO Electronics Vault. PDU KF 192.168.3.11 A3. | PDU |
Installed |
YES | |||
Lakeshore 340 | Cryogenic temperature control | K2 AO Electronics Vault. PDU KG 192.168.3.12 A1. | PDU |
Installed |
YES |
Lakeshore |
218 | Cryogenic temperature monitoring | K2 AO Electronics Vault. PDU KG 192.168.3.12 A2. | PDU |
Installed |
YES |
Motor |
power supply | Power supply for motors |
K2 AO Electronics Vault. PDU KG 192.168.3.12 A7. | PDU Installed | YES | |
Heater power supply | Power supply for heater used in cryogenic temperature control | K2 AO Electronics Vault. PDU KG 192.168.3.12 A8. | PDU |
Installed |
YES | ||
DGH A1000 | RS-232 to RS-485 serial communication converter for spectral lamp control | K2 AO Electronics Vault |
PDU Needed
N/A
Spectral lamp controller
Controls spectral lamps
K2 AO Electronics Vault
PDU Needed
. PDU KF 192.168.3.11 A3. | PDU Installed | YES | ||
Power supply for calibration lamps | Arc lamps and white light source | K2 AO Electronics Vault. PDU KG 192.168.3.12 A6. | PDU Installed | YES |
Network switch for Archon controller | Communications between waikoko-new and the Archon controller | K2 AO Electronics Vault. Network switch IP address 192.168.3.3. PDU KF 192.168.3.11 A8. | PDU Installed | YES |
Vacuum pump controller | Controls backup roughing and turbo vacuum pumps | K2 AO enclosure. NIRC2 PDU in AO 192.168.3.10 outlet A8. | PDU |
Installed |
YES | |||
Solenoid valve | Controls vacuum port from the backup turbo pump to the dewar | K2 AO enclosure. Power output from the vacuum pump controller. | No PDU |
needed | N/A | ||
Turbo vacuum pump | Used for servicing dewar and to ensure vacuum inside dewar if there is an unintended warm up | K2 AO enclosure. Power output from the vacuum pump controller. | No PDU |
needed | N/A | ||
Oil-less roughing vacuum pump | Used for servicing dewar and to ensure vacuum inside dewar if there is an unintended warm up | K2 AO enclosure. Power output from the vacuum pump controller. | No PDU |
needed | N/A | ||
Transputers | Old detector electronics | K2 AO enclosure. Electronics cabinet to be dismantled once we start science operations with Archon controller. | No PDU |
needed | N/A | |||
Archon controller | New detector electronics | K2 AO enclosure. NIRC2 PDU in AO 192.168.3.10 outlet A1. | PDU Installed | YES |
USB/FO converter power supply | USB/FO converter for signal analyzer |
attached to Archon controller | K2 AO enclosure. NIRC2 PDU in AO 192.168.3.10 outlet A3. | PDU Installed | YES |
Additional information
Need 2 PDUs to cover all NIRC2 devices in the K2 AO Electronics Vault (DONE).