Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

m obdb=0

check with s obdb must be ~0. mm for home

to put the dichroic in as pwfs@vm-pwfsserver

prtcInsertDichroic

check with show -s ao obdb and it should show ~220. mm

Modulator:

must be between 0 and 1V

amplitudes centers

Ok: 550 0.16 0.17 0.50 0.50 0.00 90.00

channels for center: k2:ao:pmod:offsetX k2:ao:pmod:offsetY

so the position must be  0< | center + amplitude| < 1

scale is ~ 1V/arcsec

KPIC DIAGRAM

Image Added

CRED2 Display (Tracking Camera)

Image Added

  1. Bring up an xterm: pwfs@vm-pwfsserver (from the k2aoserver-new VNC pull down)

2. ssh -X nfiudev@nfiuserver (the usual AO password for VNC)

3. [nfiudev@nfiuserver ~]$ cd src/sce

4 [nfiudev@nfiuserver sce]$ ./psfDispTiny.py -s /tmp/TC_Display_images.im.shm

Another option is to bring up the VNC where the FIU camera is running an eavesdrop on that:

nfiuserver:2 <usual AO password>

...

PyWFS Quick Access

Image Added

Launch with

[pwfs@vm-pwfsserver ~]$ prtcQuickAccess.py

to center the modulator:

open the loops

center modulation

PyWFS AO screens: k2aoserver-new:2

...

Instructions for Restarting the PyWFS camera (Saffira): (from Sylvain)

Symptom: PyWFS Camera (in the PyWFS status) shows red and says it is powered off

Clicking on it and rebooting/restarting the camera server does NOT resolve this.

Solution:

  1. Connect to the RTC: ssh -X prtc@prtcserver

  2. showRTProcess: it opens a window and the 2nd process from the top is partially crash

  3. Ctrl-c to restart the process

  4. Then connect to: ssh -X pwfs@vm-pwfsserver

  5. Issue command: prtcRestartCOM (takes about 5 sec, then you should be able to reacquire the camera)