Skip to end of metadata
Go to start of metadata

You are viewing an old version of this content. View the current version.

Compare with Current View Version History

« Previous Version 6 Next »


Table of Contents:


Page Status

DRAFT/INCOMPLETE


Relevant Devices

Description

Qty

Source

Part Number

Menlo Laser Frequency Comb


Relevant Functional Block Diagram


Software Actions

Action

Notes

1

Not applicable

-

Note: No KPF software actions required. That is, we don’t need to control the comb, only get telemetry values from it.


Required Adjustable Settings

Setting

When Needed

Notes

Build

Observing

Maintenance

Not Applicable

Comb settings are set and maintained by manufacturer.


Required Telemetry

Parameter

Report Frequency

Purpose

Notes

1

f_rep

TBD

Used to define comb output frequencies

Should be written to FITS header

2

f_0

TBD

Used to define comb output frequencies

Should be written to FITS header

3

Comb lock status

TBD

Ensure comb stability is locked.


Required Alarms

Parameter

Threshold

Notes

1

2


Relevant Datasheets & Manuals

Description

File

Source

1

ClientAPI.zip: documentation of and client libraries for the remoting interface of the system. The documentation is system-agnostic, describing the data-format and some of the general data structures you will encounter. The client libraries are for Python, JavaScript, C++ and C# users, each with a small bare-bones example of reading values.

Email from Tilo Steinmetz at Meno

2

API-Docs.zip: documentation of many of the classes exposed through the API. Frankly, this documentation is still pretty erratic: some parts are not documented at all while other parts still contain internals in the user-documentation. But once you have established connection to the system, this is still the best source available for details of the objects tree you see through the API

Email from Tilo Steinmetz at Meno

3

menlosystemcore_with_plugins-1.7.0-installer.exe, coreui-2.5.0-installer.exe and systemlogic.zip: releases of the PC-version of the main application and the GUI component, to allow you to install on any of your (Windows-)PCs and get them to pretend to be an LFC. Useful for testing before the actual system gets shipped. Please note: we expect to have one more bugfix release of the software and to do lots of editing of the systemlogic (which is a high-level, scriptable configuration of the system). The bugfix release is needed because the GUI still crashes sometimes during startup and the systemlogic as attached still needs some work: a few elements GUI pages are not working and the automation is still missing

Email from Tilo Steinmetz at Meno

4

5

OUTDATED

Fiber Comb Control software User Manual

From NEID Menlo comb

6

OUTDATED

Software Interface Control Document for XLMRPC-protocol

From NEID Menlo comb


Relevant Software

  • No labels