Sub-system PDUs (needed and/or already installed)
Sub-system | Function | Physical Location | Status | Keyword Control |
NIRC2 motion control and and detector host computer (waikoko) | Motion control, cold head speed control, temperature control and monitoring, detector operation with old electronics (transputers) | K2 Computer Room | PDU installed | YES |
NIRC2 detector host computer (waikoko-new) | Detector operation with new Archon controller. | K2 Computer Room | PDU installed | YES |
BlackBox SCS to FO converter | Detector operation with old transputer electronics | K2 Computer Room | PDU installed | YES |
AT-MC15 | Ethernet to 10BASE converter for AO vault and CCR terminal servers | K2 Computer Room | PDU installed | YES |
Emulex Terminal Server | Communications with CCD speed controller | K2 Computer Room | PDU installed | YES |
DGH A1000 | RS-232 to RS-485 serial communication converter for CCR speed controller | K2 Computer Room | PDU installed | YES |
CCR speed controller | Controls the speed of the two CCR cold heads | K2 Machinery Room. One one PDU outlet outlet required. | PDU Needed | NO |
Keyword history machine (moolelo) | NIRC2 keyword history dispatcher | K1 Computer Room. TCSU rack. | PDU installed | YES |
Emulex Terminal Server | Communications with motors and Lakeshores for temperature monitoring and control | K2 AO Electronics Vault | PDU Needed | NO |
DGH A1000 | RS-232 to RS-485 serial communication converter for motors | K2 AO Electronics Vault | PDU Needed | NO |
DGH A1000 | RS-232 to RS-485 serial communication converter for pupil rotator | K2 AO Electronics Vault | PDU Needed | NO |
Lakeshore 340 | Cryogenic temperature control | K2 AO Electronics Vault | PDU Needed | NO |
Lakeshore 218S | Cryogenic temperature monitoring | K2 AO Electronics Vault | PDU Needed | NO |
Motor and heater power supply | Power supply for motors and for heater used in cryogenic temperature control | K2 AO Electronics Vault | PDU Needed | NO |
DGH A1000 | RS-232 to RS-485 serial communication converter for spectral lamp control | K2 AO Electronics Vault | PDU Needed | NO |
Power supply for calibration lamps | Arc lamps and white light source | K2 AO Electronics Vault | PDU Needed | NO |
Network switch for Archon controller | Communications between waikoko-new and the Archon controller (192.168.3.3) | K2 AO Electronics Vault | PDU Needed | NO |
Vacuum pump controller | Controls backup roughing and turbo vacuum pumps | K2 AO enclosure. NIRC2 PDU in AO 192.168.3.10 outlet A8. | PDU Installed | YES |
Solenoid valve | Controls vacuum port from the backup turbo pump to the dewar | K2 AO enclosure. Power output from the vacuum pump controller. | No PDU needed | N/A |
Turbo vacuum pump | Used for servicing dewar and to ensure vacuum inside dewar if there is an unintended warm up | K2 AO enclosure. Power output from the vacuum pump controller. | No PDU needed | N/A |
Oil-less roughing vacuum pump | Used for servicing dewar and to ensure vacuum inside dewar if there is an unintended warm up | K2 AO enclosure. Power output from the vacuum pump controller. | No PDU needed | N/A |
Transputers | Old detector electronics | K2 AO enclosure. Electronics cabinet to be dismantled once we start science operations with Archon controller. | No PDU needed | N/A |
Archon controller | New detector electronics | K2 AO enclosure. NIRC2 PDU in AO 192.168.3.10 outlet A1. | PDU Installed | YES |
USB/FO converter power supply | USB/FO converter for signal analyzer attached to Archon controller | K2 AO enclosure. NIRC2 PDU in AO 192.168.3.10 outlet A3. | PDU Installed | YES |
Additional information
Need 2 PDUs to cover all NIRC2 devices in the K2 AO Electronics Vault.