Bench Isolator Motors

Bench Isolator Motors


Table of Contents:


Introduction

The optical bench within the vacuum chamber is supported by five vibration isolation pedestals. Typically these isolators have a hand-crank that can be used to adjust the height of each isolator mechanism and therefore level the table being supported.

For KPF, these five hand-cranks were replaced by vacuum-compatible stepper motors. This allows for remote leveling of the bench via computer control (while the bench is installed within the vacuum chamber).


Relevant Devices

Description

Qty

Source

Part Number

Description

Qty

Source

Part Number

Stepper Motor Controller

1

Galil

DMC-4050(16BIT)-C012-I000-I000-D4040-D4020(ISAMP)

Controller Power Supply

1

Galil

PSR-12-24

Vacuum-Compatible Stepper Motors

5

Lin Engineering

4118M-06S-DDRO

 


Relevant Functional Block Diagram

 


Cable Details

Cable

Qty

Details

Notes

Cable

Qty

Details

Notes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


Installation Details

Description

File

Notes

Description

File

Notes

1

Kodi’s Description of the System

 

2

Instructions for Setting the “Motor Off” Jumper

 

This jumper ensures the motors will not turn on when the Galil powers-up. This is especially important as these motors are a heat source within the vacuum chamber.